Split Phase Ac Motor Wiring Diagram

I was looking to use a dpdt switch with center off to do that but cannot figure out how to wire it properly and am wondering if it s possible.
Split phase ac motor wiring diagram. The phasor diagram of the split phase induction motor is shown below. The current in the auxiliary winding i a is approximately in phase with the line voltage. If you apply current to both windings and establish a magnetic field simul. Split phase motor wiring diagram the split phase motor can be found in applications requiring 1 20 hp up to 1 3 hp meaning it can turn anything from blades on a ceiling fan washing machines tubs blower motors for oil furnaces and small pumps.
The wiring diagram on the motor looks like this. It shows the run and start winding of the stator as well as the centrifugal switch cs. It has 2 contacts for the run winding and it has a black and red wire hanging out of the housing which i assume are for the start winding. The run and start stator windings are con nected in parallel.
Single phase motors are not self starting as the supply voltage is not producing a rotating magnetic field. I have an old sears craftsman 1 2 hp split phase induction motor model 12120 cat 1212 but can t find any info for wiring it so it can run both forward reverse via a switch. How does an airconditioner work. Read here to know about the split phase motor wiring arrangement and starting method of a single phase motor.
Split phase motor reversing wiring diagram this is a simplified version of a permanent capacitor split phase induction motor by simplifying we mean the coils only requires a few hundred turns of wire instead of a few refer to both the by reversing the order that the since each coil is divided in two so the diagram above figure 3 65 which has two center tapped coils represents the connection of a 4 phase unipolar stepper however motor coils must have center taps for the unipolar drive. Another split phase capacitor run type of electric motor utilizes a capacitor transformer unit and is of the split phase squirrel cage type with the main and auxiliary winding s physically displaced in the stator. This may be achieved by converting a single phase supply into two phase supply through the use of an additional winding. Thus there exists the time difference between the currents of the two windings.
To make a single phase induction motor self starting we should somehow produce a rotating magnetic field. Then how do the single phase motors what we use everyday are self starting. The centrifugal switch is a normally close control device that is wired into the start winding. Know the method used to reverse a single phase induction motor.
Before going to the operation and characteristics of split phase induction motor we should first understand why single phase induction motor is not self starting. You can opt for a 1 ton split ac a 1 5 ton split ac or a 2 ton split ac. Split phase resistance start motors figure 17 10 is a basic one line diagram of the split phase motor. The motor is a 3 4 horse dayton split phase.